EasyManua.ls Logo

Electra WNG 9 - Page 18

Electra WNG 9
548 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
2-8
PRODUCT DATA SHEET
Revision Y05-03 Service Manual - WNG
Model Indoor Unit WNG 24
Model Outdoor Unit OU7-24T
Installation method WALL MOUNTED
Characteristics Units Cooling only Cooling Heating
Capacity (1)
Btu/hr 23220 23220 25130
kW 6.81 6.81 7.37
Power input (1) kW 2.26 2.26 2.4
COP (1) W/W 3.01 3.01 3.07
Energy efficiency class B B D
Power supply V/ Ph /Hz 400/50/3N
Rated current A 4.1*3 4.4*3
Starting current A 55
Circuit breaker rating A 10*3
INDOOR
Fan type & quantity CROSS FLOW *1
Fan speeds H/ M/ L RPM 1300 1200 1100
Air flow (2) H/ M/ L m³/hr 990 930 840
External static pressure Min-Max Pa N/A
Sound power level (3) H/ M/ L dB(A) 58 55 53
Sound pressure level (4) H/ M/ L dB(A) 45 42 40
Moisture removal L/hr 2.3
Condensate drain tube I.D mm 16
Dimensions W/ H / D mm 1060 295 210
Weight kg 15
Package dimensions W/ H / D mm 1115 350 260
Packaged weight kg 18
Units per pallet Units 16
Stacking height Units 8
OUTDOOR
Refrigerant control CAPILLARY TUBE
Compressor type, model ROTARY
Fan type & quantity AXIAL*1
Fan speeds H / L RPM 850 720
Air flow H / L m³/hr 3100 2600
Sound power level H / L
dB(A)
67 62
Sound pressure level (4) H / L
dB(A)
58 54
Dimensions W/ H / D mm 900 680 340
Weight kg 74
Package dimensions W/ H / D mm 985 730 406
Packaged weight kg 74
Units per pallet Units 6
Stacking height Units 2
Refrigerant type R410A
Refrigerant chargless distance kg/m 2.035/12.5
Additional charge g/m
12.5m<Add 350g<15m
12.5m<Add 1040g<20m
Connections
between units
Liquid line In. 3/8
Suction line In. 5/8
Max. tubing length m. 20
Max. height difference m. 15
Operation control type LCD REMOTE CONTROL
Heating elements kW
Others All season kit Factory option
(1)
Rating conditions in accordance with ISO 5151, ISO 13253 (for ducted units) and EN 14511.
(2)
Airflow in ducted units; at nominal external static pressure.
(3)
Sound power in ducted units is measured at air discharge.
(4)
Sound pressure level measured at 1 meter distance from unit

Table of Contents