EUROFLEC 20/36
4.10. Evaporator
The evaporator fitted to the appliance is located in
the freezer compartment and consists of a traditional
NOFROST battery.
4.11. Condenser
The ventilated condenser is located in the
base of the appliance.
4.12. Flap-operated mechanical thermostat
The flap-operated mechanical thermostat controls the flow of air
into the refrigerator compartment. When the temperature
detected by the external (in air) bulb reaches the cut-in
temperature, the flap opens, thus allowing cold air to enter from
the freezer compartment.
When the temperature in the refrigerator compartment reaches
the cut-out value, the flap re-closes and prevents further air
from being ducted into the refrigerator compartment.
By the STAND-BY position the flap does not stop completely
the cold air to flow in, but regulates the temperature of the
freezer compartment around +15°C (only if in the refrigerator
compartment there is no food, this function is used to keep the
door closed thus avoiding the formation of bad odours).