EasyManua.ls Logo

Electrolux EUROFLEC - NTC sensors failure

Electrolux EUROFLEC
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
EUROFLEC 24/36
6.5. NTC sensors failure
When there is a failure in NTC sensors, during normal mode the three LEDs (b), (c) and (d) blink.
The appliance is controlled in the following way:
failure
sensor
failure working time compressor
cycles
defrost time
First start 6 hours controlled by
Air NTC
22 minutes Evaporator NTC
sensor
(no adaptivity)
During working latest time before
failure
controlled by
Air NTC
22 minutes
First start controlled by evap.
NTC
10 min pause
15 min run
controlled by evap.
NTC
Air NTC sensor
(adaptivity)
During working controlled by evap.
NTC
latest times before
failure
22 minutes
First start 6 hours 10 min pause
15 min run
22 minutes Evaporator NTC
sensor + Air NTC
sensor
(no adaptivity)
During working latest time before
failure
latest times before
failure
22 minutes