EUROFLEC 34/36
9.6. Control and power board (MB)
- remove the back panel by unscrewing the two screws used to secure the back panel;
- after disconnecting the connectors on the control and power board, unscrew the screws which secure
the power board to the cabinet;
- to access the control and power board, unhook the lug (1) and remove the housing (2).