EUROFLEC 32/36
- remove the drainage duct (which is pressure-fitted)
- remove the fan;
- raise the evaporator battery slightly and remove the defrosting heater
- these operations make it possible to access the thermal cut-outs (1), the evaporator sensor (2), the
ambient sensor (3) and the freezer compartment door switch.