EasyManua.ls Logo

Electrolux EWM2500 - Page 46

Electrolux EWM2500
56 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SOI/DT 2007-02 dmm 46/56 599 38 60-23
Alarm Possible fault Action/machine status Reset
E58
Motor defective; Wiring defective on inverter for motor, inverter board defective,
abnormal motor operation (motor overloaded).
Cycle stops with door locked (after 5 attempts). RESET
E59
Motor defective; Wiring defective on inverter for motor;
Inverter board defective.
Cycle stops with door locked (after 5 attempts). RESET
E5A
Inverter board defective. NTC open (on the inverter board).
Overheating caused by continuous operation or ambient conditions (let appliance cool
down)
Cycle stops with door locked (after 5 attempts). RESET
E5B
Wiring defective, Inverter board defective Cycle stops with door locked (after 5 attempts). RESET
E5C
Inverter board defective, the masters voltage is too high (measure the masters voltage) Cycle stops with door locked (after 5 attempts). RESET
E5D
Line interference, Wiring defective, defective main board or inverter board Cycle stops with door locked (after 5 attempts). RESET
E5E
Defective wiring between main board and inverter board, Defective inverter board,
defective main board.
Cycle stops ON/OFF
E5F
Defective inverter board, Defective wiring, defective main board Cycle stops with door locked (after 5 attempts). RESET
E61
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. The heating phase is skipped. START/RESET
E62
NTC sensor faulty; heating element faulty; wiring faulty; PCB faulty. Safety drain cycle – Cycle stopped with door open. RESET
E66
PCB faulty . Safety drain cycle – Cycle stopped with door open. RESET
E68
Earth-leakage between heater and earth. Cycle blocked with door open. RESET
E71
Faulty NTC sensor; Wiring faulty;
PCB faulty.
Heating is skipped. START/RESET
E74
NTC sensor improperly positioned; Faulty NTC sensor; Wiring faulty; PCB faulty. Heating is skipped. START/RESET
E82
PCB faulty (Wrong configuration data). Selector, wiring ---------------- RESET
E83
PCB faulty (Wrong configuration data). Selector, wiring Cycle cancelled. START/RESET
E91
Wiring faulty; Faulty control/display board
PCB faulty.
---------------- RESET
E92
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted. OFF/ON START
E93
Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON
E94
Incorrect configuration data; PCB faulty. Cycle interrupted. OFF/ON
E95
PCB faulty. Cycle interrupted. RESET
E97
Faulty PCB (Wrong configuration data). Cycle interrupted. RESET
E98
Incompatibility between main board and Inverter Cycle interrupted. OFF/ON
E99
Main PCB. Cycle interrupted. OFF/ON
E9B
Display board.
Cycle interrupted.
Reset
E9C
Display board. Cycle interrupted.
Reset
E9D
Display board. Cycle interrupted.
Reset
E9F
Main PCB. Cycle interrupted. OFF/ON

Table of Contents