ENV06 EWM11xx EWM21xx EWM25xx/35xx
QUICK GUIDE AND APPLIANCES LIST 48/176 599 72 40-80
Alarm Possible fault Action/machine status Reset Alarm
E82
Error in selector reset position PCB faulty (Wrong configuration data). ---------------- RESET
E83
Error in selector reading PCB faulty (Wrong configuration data. Cycle cancelled. START/RESET
E91
Communication error between PCB and
display board
Wiring faulty; Control/display board faulty:
PCB faulty.
---------------- RESET
E92
Communication incongruence between
main PCB- display board
(versions not compatible)
Wrong control/display board;
Wrong PCB (do not correspond to the model).
Cycle interrupted. OFF/ON
E93
Incorrect configuration of appliance PCB faulty; (Incorrect configuration data). Cycle interrupted. OFF/ON
E94
Incorrect configuration of washing cycle PCB faulty; (Incorrect configuration data). Cycle interrupted. OFF/ON
E95
Communication error between
microprocessor and EEPROM
PCB faulty. Cycle interrupted. RESET
E97
Incongruence between programme
selector and cycle configuration
Faulty PCB (Wrong configuration data). Cycle interrupted. RESET
E98
Communication error between main
board - Inverter
Incompatibility between main board and Inverter. Cycle interrupted. OFF/ON
E9H
Communication error between
microprocessor and FLASH memory
Display board. ----------------
OFF/ON
RESET
E9C
Machine configuration error Display board. ----------------
OFF/ON
RESET
E9d
Clock faulty Display board. ----------------
OFF/ON
RESET
E9F
Communication error between PCB and
remote devices
Wiring between PCB and Inverter faulty; PCB faulty; Inverter faulty. Cycle interrupted. OFF/ON
EA1
Drum positioning (DSP) faulty Motor belt broken; Wiring faulty; PCB faulty; DSP sensor faulty. Positioning phase skipped.
ON/OFF
RESET
EA6
DSP door opening faulty Motor belt broken; Wiring faulty; Drum cover open. Motor faulty; PCB faulty. Cycle paused.
ON/OFF
RESET
EC1
Solenoid valve blocked with flowmeter
working
Wiring faulty; Solenoid valve faulty/blocked, PCB faulty.
Cycle blocked with door closed.
Drain pump always works (5 min., then
it stops for 5 min. ecc.).
RESET
EC3
Problems with Weight sensor (no signal
or out of limits)
Wiring faulty; Weight sensor faulty; PCB faulty. ---------------- START/RESET
Ed1
Data communication error between WD
board and PCB
Wiring faulty between PCB and WD board; WD board faulty; PCB faulty. Cycle interrupted. OFF/ON
Ed2
Drying heating element relay 1 faulty
Wiring faulty between WD board and thermostats; thermostats faulty; WD board
faulty, PCB faulty.
Cycle blocked with door open. RESET
Ed3
Drying heating element relay 2 faulty
Wiring faulty between WD board and thermostats; thermostats faulty; WD board
faulty, PCB faulty.
Cycle blocked with door open. RESET
Ed4
Relay which commutates power between
washing heating element and drying (in
the WD board)
Wiring faulty; WD board faulty; PCB faulty. Cycle blocked with door open. RESET
Ed6
No communication between PCB and
display board (INPUT)
Wiring faulty between PCB and programme display board; PCB faulty. ---------------- OFF/ON