EasyManua.ls Logo

Electrolux T4250 - Error Log and Parameter Reading

Electrolux T4250
70 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4. Programmes
4
Service
manual
487 05 40 31
4.8
Group 3 - Log
Readable parameters
All error codes are registered in the error log.
Beside error codes E 01 - E 18, there are a number of internal error codes which are not
displayed but only registered in the error log.
Error codes registred in the log that are not on the error code list (E 01-E 18) in this
manual should be reported to the manufacturer.
Factory
setting
Para-
meter /
group
Comments
3 01 Last error log n - info. Shows last occured error and time
3 02 Error log (n-1) - info. Second latest error code and time
3 03 Error log (n-2) - info. Third latest error code and time
3 04 Error log (n-3) - info. Fourth latest error code and time
3 05 Error log (n-4) - info. Fifth latest error code and time
3 06 Not in use
3 07 Selecta software version - info. Software version
3 08 Not in use
3 09 Identification of parameter part 1 info. Identification of version
3 10 Identification of parameter part 2 info. Identification of version
3 11 Production ID number - info. Identification of production data
Designation Range Step
See example on the next page which shows the latest error code E08 which occurs after
220 hours of operation.

Other manuals for Electrolux T4250