487 05 40 31
4.15
4. Programmes
4
Service
manual
Group 6 - Setting maximum values
Adjustable parameters
Factory
setting
Para-
meter /
group
Comments
6 01 Number of P programmes 1 – 9 1 0 Coin
2 AHL AutoStop
3 AHL RMC
5 OPL AutoStop
9 OPL RMC
6 02 Inlet temperature 4300/30x30 Gas 80 - 180°C / 176 - 356°F 1 180°C / 356°F
4250/4350 Gas 80 - 155°C / 176 - 310°F 155°C / 310°F
El 80 - 155°C / 176 - 310°F 155°C / 310°F
4190 El 80 - 180°C / 176 - 356°F 180°C / 356°F
4130 El/condens 0
ALL Steam - 0
Designation
Range
Step
First 2 digits
Last 2 digits
=
+
140°C
Example
Warning!
Incorrect parameter setting can
damage the dryer.
Factory
setting
Para-
meter /
group
Designation
Dryer/heating type Range Step
Factory
setting
Para-
meter /
group
Comments
6 03 Max. time on time control 10 – 90 min 1 90 Max. time which can be selected (also coin)
6 04 Max. time on P programs 30 – 90 min 1 90 Max. time on AutoStop or RMC
6 05 Autostop 30 - 70°C / 50 - 70°C Depending of the dryer type
86 - 160°F
6 06 Error code E18 0 / 1 1 0 0 = activated / 1 = deactivated
6 07 Error code E08 flashes when the
loading door is open 0 / 1 1 0 0 = activated / 1 = deactivated
6 08 Vaccum error timer 0 - 15 sec. 1 13 Time to pass before vacuum signal appears
6 09 Option - - -
6 10
Option - - -
Designation Range