23
c) Change Functions - The display will toggle between the First and Second Low Fuel Alarm Limits
by pushing the Right "F. RES" button with the right digit blinking or by pushing the Left "F. to
DES" button with the left digit blinking. The First Low Fuel Alarm Limit is always displayed with
a bar in the upper left corner of the display and the Second Low Fuel Alarm Limit is always
displayed with a bar in the lower left corner of the display.
d) To Exit - To exit the Pilot Programming Settings for the "USED" Display Mode, momentarily
push both the "F. to DES" and "F. RES" buttons at the same time. The programmed values will
be stored in memory and no internal batteries or external power are required to store this infor-
mation for life.
4. Setting the Time to Empty Alarm and the Reoccurring Fuel Used
Alarm in the "T. to E." Display Mode:
In the “T. to E.” display mode the following alarms may be set:
Time to Empty Alarm - The Time to Empty Alarm may be programmed
to blink the Low Fuel Warning LED when the Time to Empty calculated
by the FP-5L reaches your programmed setpoint. Pushing any button or
switch will turn off the blinking LED. This limit may be set to remind you
to switch tanks or when a specified Time to Empty has been reached. In
the “T. to E.” Display Mode a bar in the upper left corner of the display
will be shown when this limit has been violated. Programming this alarm
to “0:00” disables the alarm.
Reoccurring Fuel Used Alarm - The Reoccurring Fuel Used Alarm
may be programmed to blink the Low Fuel Warning LED each time the
fuel used reaches the programmed limit. Example: You have 40 gallons of
fuel on board. You set the Reoccurring Alarm to 5 gallons. You will get
an alarm every 5 gallons of fuel used (i.e., when your fuel levels reaches
35, 30, 25, 20, etc. gallons). Pushing any button or switch will turn off the
blinking LED. This limit may be set to remind you to switch tanks or to
check your fuel levels at specified fuel levels. Programming this alarm to
“000” disables the alarm.
To program the Time to Empty and Reoccurring Alarms, perform the
following steps:
A. Select the “T. to E.” Display Mode.
B. Momentarily push both the "F. to DES" and "F. RES" buttons. A bar will appear in the upper left
corner of the display and the left digit will be blinking. You are ready to program the Time to Empty
Alarm limit.
C. Set the Time to Empty and Reoccurring Alarm limits using the following procedure:
a) Select a Digit - The "F. to DES" and "F. RES" buttons move the blinking digit to the right or to
the left.
005
Gal
Blinking Digit
1:00
Blinking Digit