11 Internet Options
iConnect
Installation Manual
67
11. Internet Options
The following options concern the configuration of the GPRS and Ethernet Communication Modules. In most cases, the
Internet options will be pre-programmed as defaults and you will not be required to change any of the settings apart
from the CPID and password for each customer.
11.1. ELAS Connection Parameters
The following parameters, required to connect Control System to ELAS, are set by ELAS administrator.
11.1.1. Proxy Address
To edit the Proxy Address:
1. From the Programming menu, select Communications, Internet, Proxy Address [9571].
2. Enter the Proxy Address IP provided by your ELAS administrator. Use the "1" key to enter ".",
key to insert and
the
key to delete one character at a time. Press '√ʹ when finished.
11.1.2. XML Proxy Port
To edit the XML Proxy Port:
1. From the Programming menu, select Communications, Internet, XML Proxy Port [9572].
2. Enter the XML Proxy Port provided by your ELAS administrator. Use the "1" key to enter ".",
key to insert and
the
key to delete one character at a time. Press '
√ʹ when finished
.
11.2. Control System Parameters
The following parameters, required to connect Control System to ELAS, should be provided by your ELAS
administrator.
11.2.1. CP ID
To edit the Control System ID:
1. From the Programming menu, select Communications, Internet, CP ID [9573].
2. Enter the unique Control System ID provided by your ELAS administrator to connect the Control System to
ELAS. Use the "1" key to enter ".",
key to insert and the key to delete one character at a time. The ID
length must be six up to sixteen characters. Press '
√ʹ when finished.
11.2.2. CP Password
To edit the Control System Password:
1. From the Programming menu, select Communications, Internet, CP Password [9574].
2. Enter the Control System Password provided by your ELAS administrator to connect the Control System to
ELAS. Use the "1" key to enter ".",
key to insert and the key to delete one character at a time. The
password length must be six up to sixteen characters. Press '√ʹ when finished.
11.2.3. ELAS Connection On/Off
To enable/disable ELAS connection option:
1. From the Programming menu, select Communications, Internet, ELAS Connect [9575].
2. Select Enabled or Disabled.