12 Home Automation Programming
iConnect
Installation Manual
71
12.2.3. On by Arm
The On by Arm feature activates the HA unit when the system is armed using any of the arming methods. The amount
of time the HA unit is activated is determined by the Pulse Time see p. 72, 12.2.8 Pulse Time. If the Pulse Time is
programmed as "Toggle", disarming the system switches the HA unit off.
To program the On by Arm feature:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select On by Arm [#05].
4. Select Enabled or Disabled.
12.2.4. On by Alarm
On by Alarm is a feature designed for use with X10 sirens. When an alarm occurs, the HA unit (i.e. siren) is activated
for the duration of the siren cutoff see p. 42, 7.7.2 Siren Cut-Off. The X10 siren sounds a continuous pattern for
intrusion/panic alarms and a pulsed pattern for fire alarms.
To program the On by Alarm feature:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select On by Alarm [#06].
4. Select Enabled or Disabled.
If an HA unit is programmed to be activated by the On by Alarm feature, program all other
operation modes (On by Arm, Randomize, etc.) as disabled.
Do not program more than one HA unit to be activated by the On by Alarm feature. If more
than one siren is required, set all sirens with the same House and Unit code.
12.2.5. Keyfob Control
Each keyfob (EL-4714), offers control of up to two individual HA units. This programming option allows you to enable
or disable this feature per HA unit.
To program the keyfob control option for an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select KF Ctrl [#07].
4. Select Enabled or Disabled.
12.2.6. Telephone Control
Via SMS or DTMF, you can send commands to the system in order to control various HA units. This option allows you
to enable or disable this feature for each HA unit.
To program the telephone control option for an HA unit:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select TEL Ctrl [#08].
4. Select Enabled or Disabled.
12.2.7. Randomize
When the system is fully armed between the hours 9:00pm and 6:00am, the Randomize feature turns HA units on and
off at random. This gives the impression that the house is occupied and acts as a deterrent against potential intruders.
To program an HA unit to be included in the Randomize feature:
1. From the Programming menu, select HA Programming, HA Units [961].
2. Select an HA unit (01-16).
3. From the HA unit’s sub-menu, select Randomize [#09].
4. Select Enabled or Disabled.