8.4 Log file "BATREC.log"
When in use, the BATLOGGER automatically writes a log file “BATREC.log” in text format to the SD card. Every
text line is preceded by the serial number (SN) of the BATLOGGER writing the log. When changing the SD card to
another logger, or removing it and re-inserting it again, the log file will be extended and new log information
appended to the “BATREC.log” file. Deleting WAVE files through the menu of the BATLOGGER does not affect the
“BATREC.log” file.
However, formatting the SD card will also erase the “BATREC.log” file!
In the file ”BATREC.log”, all activities of the BATLOGGER are listed chronologically.
Events like starting up or shutting down the BATLOGGER are logged accurate to the minute, while logging of the
normal recording activity only happens every 15 minutes.
SN1021 22.07.2009 21:37 - power on BATLOGGER #1021 was switched on
SN1021 22.07.2009 21:37 - record mode started Recording started
SN1021 22.07.2009 21:37 - record mode stopped by user Recording cancelled by user
SN1021 22.07.2009 21:42 - record mode started Recording started again
SN1021 22.07.2009 23:45 - listening T = 21 VB = 3.912 BATLOGGER is in recording mode and waiting
SN1021 23.07.2009 00:00 - listening T = 20 VB = 3.908 for a triggering event, with indication of
SN1021 23.07.2009 00:15 - listening T = 19 VB = 3.905 temperature (21°C) and battery voltage (3.912V)
SN1021 23.07.2009 00:30 - listening T = 19 VB = 3.905
SN1021 23.07.2009 00:45 - sleeping The BATLOGGER went into sleep mode
SN1021 23.07.2009 02:45? - wakeup time reached Automatic wake-up after sleep mode
SN1021 23.07.2009 02:45? - listening T = 17 VB = 3.891 ?: no valid GPS signal found (time is taken
SN1021 23.07.2009 03:00 - listening T = 17 VB = 3.886 from internal clock in this case)
SN1021 23.07.2009 03:15 - listening T = 16 VB = 3.882
SN1021 23.07.2009 03:30 - listening T = 16 VB = 3.877
SN1021 23.07.2009 03:45 - listening T = 16 VB = 3.871
SN1021 23.07.2009 04:00 - listening T = 15 VB = 3.865
SN1021 23.07.2009 04:15 - listening T = 15 VB = 3.860
SN1021 23.07.2009 04:30 - listening T = 15 VB = 3.856
SN1021 23.07.2009 04:45 - listening T = 15 VB = 3.852
SN1021 23.07.2009 05:00 - listening T = 15 VB = 3.847
SN1021 23.07.2009 05:15 - listening T = 15 VB = 3.843
SN1021 23.07.2009 05:30 - listening T = 16 VB = 3.838
SN1021 23.07.2009 05:45 - listening T = 16 VB = 3.833
SN1021 23.07.2009 05:55 - shutdown The BATLOGGER was shut down
Example of a quick startup of the logger
with the manual triggering and cancelling of a recording:
SN1021 25.07.2009 19:47? - power on
SN1021 25.07.2009 19:47? - record mode started
SN1021 25.07.2009 19:47? - record mode stopped by user
SN1021 25.07.2009 19:47? - shutdown
Exampe of another message that may appear:
SN1021 25.07.2009 19:47? - microphone removed
In interval mode, the pausing will be indicated with the following entry:
SN1021 27.07.2009 02:45 - snooze
BATLOGGER Manual Elekon AG Nov. 2012 24/28