MAINTENANCE
Element4 Gas Fireplaces EuropeanHome.com
Natural Gas Injector - marked 1200
Propane Gas Injector - marked 320
A burner orice is shown in below. The NG orices are marked 1200, LP orices are marked 220.
REPLACEMENT PARTS
E4-SA-LPCK-100H-04 LP Conversion Kit
REPL-E4-GS-1T-01 Replacement Primary Thermocouple
REPL-E4-GS-2TC-01 Replacement 2nd Thermocouple
REPL-E4-GS-CM-01 Replacement Receiver
REPL-E4-GS-RC-01 Replacement Remote Control
THERMOCOUPLE MAINTENANCE
The Element4 replaces have two thermocouples; one next to the pilot
and one opposite the pilot side of the main burner. The completeness and
operation of both must be checked. A qualied installer must conrm that
both thermocouples are in place and not damaged. While checking the
thermocouple, please ensure that the ignitor rod is not cracked as well.
VENT MAINTENANCE
The following venting system inspection by a qualied service technician
is recommended every six months:
1. Inspect for excessive condensation, e.g. water droplets forming in
the inner lining and subsequently dripping out of the joints. This can
cause corrosion in the system.
2. Check for corrosion in areas exposed to the elements. Where rust
spots or holes have appeared, these must be immediately replaced.
3. Ensure that there is no foreign material in the vents. Survey by
removing the cap and shining a light down the vent.
4. Check all joints and pipes to make sure that nothing has been
disturbed or loosened.