OPERATING the FIREPLACE
Element4 Gas Fireplaces EuropeanHome.com
MANUAL KNOB IN
ON POSITION
MAIN VALVE KNOB
IN ON POSITION
RESET BUTTON
Note! For normal operation the MANUAL knob on the gas valve cannot be in the MAN position; it must be fully in the ON position.
BEFORE THE FIRST FIRE
1. Make certain that all construction materials have been removed from inside and around the replace and the replace has
been cleaned of any construction dust. Clean the glass BEFORE and AFTER the rst re.
2. Conrm that the gas valve is properly connected and bled.
3. Check the gas supply for leaks and proper pressure. --- Refer to the table in “Appliance Ratings” section.
4. Check that the venting is unobstructed and in proper working condition.
5. PROPERLY PLACE, CLAMP, AND SEAL THE GLASS PANELS.
6. Ensure the receiver is plugged in with AC Adapter OR Batteries... NOT BOTH.
7. Place the three AAA batteries into the remote control and conrm that it will communicate with the receiver by pressing
the ON/OFF button. If necessary pair the remote and receiver.
8. Follow USING THE REMOTE CONTROL ELECTRONIC IGNITION SEQUENCE to setup and use remote.
PAIRING THE REMOTE AND RECEIVER (System Reset)
From the factory, the remote control will communicate with the receiver; they are ‘paired’ and should need no further attention. If
the receiver does not respond to commands from the remote they should be paired to each other. This is done as follows:
1. Press and hold the receiver reset button using a small, long tool until you hear the second of two beeps. After the second
beep release the reset button.
2. Press and hold the button on the remote until you hear the second of two beeps. Release the button.
If you hear one long beep, this indicates the pairing sequence has failed or the wiring is incorrect.
(This knob is AUTOMATIC and will
turn o when the replace is turned
o & on when the replace is turned
on.)