User instructions
INPUTS MENU
51
6.1.8 Inputs Menu ! Input Sensitivity Settings
“Audio Mode” & AUTO sts
The option “Left = Right
:” set to “TRUE” forces both L and R Stereo inputs to the
same attenuation level, otherwise each stereo channel is attenuated by the level sto-
red in “L
eVel R” and “LeVel L”. “PreEmphasys” may be 0, 25, 50 or 75 mS.
“Aux1(%):” and “Aux2(%): ” specify the attenuation levels of the aux channels input.
“Pilot Level (%):” and “Pilot Phase:” specify the percentage of pilot tone and its pha-
se in degrees.
“Clipper Level:”, expressed in kilohertz, indicates the deviation level beyond which
the protection must be activated, when “ Enable:” is set to “TRUE”.
“PLLReference10MHz” set to “INTernal” forces to use the VCO’s built in reference,
whereas set to “EXTernal” takes an outside reference (such as a GPS).
In the last case, the signal must be applied to the appropriate connector placed on
the back if this option is present.