41How to active
6.5.4.4 MONO
To use a mono signal, select this mode on the display by turning the encoder and press
to confirm.
Apply the signal to the connector XLR MONO/RIGHT on rear panel.
The audio signal can be both balanced and unbalanced. In the latter case there is a
reduction of 3dB level.
In addition there are two other possible inputs :
6.5.4.5 AES/EBU
To use a signal AES/EBU is sufficient apply the signal to the XLR dedicated, located on
the rear panel.
The signal is automatically recognized.
For more details on settings, see “User Interface” paragraph in section “Use instruc-
tions” section (User Manual).
6.5.4.6 AUXILIAR SIGNALS (RDS/SCA)
To use an auxiliary signal is sufficient apply the signal to the corresponding BNC connec-
tor, located on the rear panel.
For more details on settings, see “User Interface” paragraph in section “Use instruc-
tions” section (User Manual).
6.6 Turn on
To turn on the unit, rotate the encoder until highlight the second tab of the horizontal
menu.
Press the encoder to make display the written RFON.
In LOCAL mode, you have a situation of conformity where occurs that:
• the 4 indicators on the left side are off;
• the frequency is set to match the desired;
• the output power corresponds to the desired;
• the reflected power is zero or low value;
• Vu-Meter indicates the value 0dB.
After all phases of installation and programming, turn the unit in REMOTE mode using
the key switch.
In REMOTE mode, you have a situation of conformity where occurs that:
• PLL LOCK LED is lit;
• ON AIR LED is lit;
• MAINS LED IS LIT;
• all remaining LEDs are off.
Warning: You should keep a copy of the key in a secure location of the station.