Page 10(630) 574-8484 2000002005
(Rev. B - 01/25)
Elkay Manufacturing Company
DSSBF8SP DSSBF8SP-W1
6. Startup
1. Make sure that there are no leaks on the drain
connections and installed as per local regulations.
2. Plug-in the water cooler unit.
3. Once power is applied to the bottle ller, the GREEN
LED light will illuminate showing good lter status
along with the LCD Bottle Counter.
4. Verify proper dispensing by placing cup or any
object infront of sensor area and verify water
dispenses.
Note: The rst initial dispenses might have air in line
which may cause a sputter. This will be eliminated once
all air is purged from the line.
5. Check all the lines and connections for water leaks.
Repair connections if necessary.
6. Dispense at least two gallons of water to bleed o󰀨
any trapped air from supply lines and ne carbon
particles from the lter. If there are no leaks and unit
is functioning correctly, re-install the front cover by
installing the two hex screws on the bottom side of
the cooler using a 5/16” socket or nut driver.
7. Upon initial startup, the plastic bottles saved
indicator panel should show several bottles saved
due to the water used to initially start up of the unit.
GREEN: 0 - 80% of Filter Life or 0 - 11
Months.
YELLOW: 80 - 100% of Filter Life or 11 - 12
Months (Whichever Comes First).
RED: 100% Plus of Filter Life or 12
Months (Whichever Comes First).
7. Accessing the Programming Button
1. Remove the bottle ller top cover by removing the
four phillips screws using a phillips screwdriver. Do
not discard the screws, they are required for re-
assembly.
2. Locate the programming button at the top left side of
the unit on the control board.
Lower Front