Page 9
(630) 574-8484 2000002005
(Rev. B - 01/25)
Elkay Manufacturing Company
DSSBF8SP DSSBF8SP-W1
7. Remove the top access panel by removing the four
phillips screws on the top of the cooler unit using a
phillips screwdriver.
8. Connect the unit water line to shut-o valve.
Note: Shut-o valve not shown (installer supplied part).
9. Connect the water inlet tube to the inlet of lter
assembly.
10. Installation of lter.
a. Remove the lter from the carton.
b. Remove the protective cap.
c. Mark the current date on the water lter label.
d. Attach the lter to the lter head with label facing
outward by rmly inserting into the head and by
rotating the lter head clockwise, if required.
Note: Filter label should be readable from the front of
the lter during installation.
11. Use the four phillips screws to install the top access
panel on top of the cooler unit. Tighten the four phillips
screws fully using a phillips screwdriver.
12. Secure the cooler unit to the oor using the existing
holes in the base plate with anchor fasteners.
Top Access
Panel
Screw
Filter
MMDDYY
Water Inlet
Tube
Filter Inlet