F1
F3
F2
Spider web (data adjuster)
P01
P02
P03
P04
P05
P06
30-99
30-99
05-30
05-30
20-50
10-50
80
65
06
10
30
30
Code no.
Value range
Default value
Details
Opening speed
Closing speed
Buffer speed when opening
Buffer speed when closing
Braking distance when opening
Braking distance when closing
If value is in 10-20, you should adjust P02 and
P04 to avoid door leaves hitting each other.
P07
P08
P09
P10
01-03
01-03
01-03
20%-80%
02
02
02
60%
Auto reverse force when opening
Holding force-closed
Partial opening
Auto reverse force when closing
P12
P13
P14
P15
P16
00-01
00-01
00-02
00-01
00-01
00
00
00
00
01
Aux lock type
Battery monitoring
Battery mode
Fire alarm mode
Fire alarm equipment
P11 00-60 6
Door hold time (0-60S)
(00:lock with power,01:lock without power)
(00:disabled,01:enabled)
(00:open,01:closed, 02:automatic)
(00:open , 01:closed)
(00:NO,01:NC)
And press
P+
P+
P-
P-
EXIT
P 01
OPENING
FAST SPEED
99
Data setting: press button F2 and to select
code no. P01 to P25. There are 25 items can
be setted as customer requested.
button F1 and F3 to set the value of each code.
26
*
Spider Web (Data Adjuster)