PROBLEM SOLVING GUIDE ELMECO SLUSH MACHINE MODEL FCM
P09 – Control board’s screen blinks. When MENU button
pressed and released "ALARM VOLTAGE" come on the
screen.
Problem
There is a fluctuation in the supply voltage exceeds +/- 10%.
Reason_1
The power supply to the machine is insufficient. Most likely due to multiple pieces of
equipment plugged in on one circuit/breaker. We always recommend having a dedicated circuit
for our slush machines.
Also, we recommend eliminating any extension cords and electrical splitters.
Solution_1
It is necessary to ensure an adequate power supply to the slush machine. If the alarm comes
back, it means that the power supply is still not adequate; Turn off the lights of the lids in
order to decrease the absorption; this precaution could restore the functioning of the slush
machine without the alarm.
Notes: If the slush machine is set up on BIB AutoFill System, shut down both slush machine
and autofill system before securing proper power supply.