I
17
CLASS MEANING 6601 6611 8879
YES = the monitor switches on when
a panel call is made (not for 6601AU or 6611AU)
YES = the green led is managed
as door open indicator
YES = if the F1 / F2 pushbutton is programmed
directly on a specific panel, only panels 1 to 8 can
be programmed
NO = only panels 9 to 15
YES = the device is working in porter
switchboard mode
YES = group G3 functions only for
external calls
YES = group G4 functions only for
internal calls
YES = eliminates the click sound
when a valid key is pressed
YES = does not activate the call repeater output for
intercommunicating calls
YES = group G1 functions only for
external calls
YES = group G2 functions only for
internal calls
YES = the monitor / interphone dos
not ring for intercommunicating calls
YES = the monitor / interphone
dos not ring for calls from panels
[YES] pressing the door lock push-button ends
the conversation (default value in model /F of monitor)
NO = the door lock push-button operates normally
From version 4 of monitor and entrance panels.
[YES] to activate the audio connection press
the talk/listen push-button. To deactivate the audio
press the push-button again (default value on model
/F of monitor).
NO = To activate the audio connection the talk/listen
push-button must be kept pressed.
From version 4 of monitor and entrance panels.
FLAG PROGRAMMING
Valid only for some Vimar products.
[YES] the square button (self-start) becomes the sec-
ond function regardless of the position of the me-
chanical switch.
NO = has the self-start function.
Valid only for some Vimar products.
[YES] there is home automation.
NO = (Default)
Usually used for a group master.
[YES] the call is accepted, and then the secondary
units ring, even if the group master has ringtone off
and therefore does not ring.
NO = if a group master turns off the ringtone none
rings and there is a warning on the entrance panel.
[YES] the device has no timeout for the intercommu-
nicating conversation. For it to work properly, both
parties talking to each other must have it on YES.
NO = (Default) and the intercommunicating conver-
sation lasts at most 5 minutes.
[YES] After the panel ring tones the monitor answers
automatically. Even the flag “T./L. On/Off:NO²”must
be set to YES.
NO = No automatic answer (default).
[YES] If it is programmed for a head group, this latter,
at the call reception from the push-button module
type 6120, will inform the other members that it is
ringing. If it is programmed for the group members,
they will answer at the call from a type 6120 to their
head group ringing. In this way it is possible to divide
the calls between external, internal and outdoor calls.
NO = No reaction.