4.2 ELECTRICAL WIRING
Warning: This power pump demand licensed or certified electrician
or qualified pool installer to ensure there is adequate protection
between the pump motor and mains power supply according to
individual countries safety code.
The pump has power cord with plug attached on the plug, plug it to a
power socket with circuit breaker to isolate the motor from the mains power for over load
protection. The circuit breaker rating should refer to the electrical specification of individual
pump working voltage and power.
The power has to be with a Residual Current Device (RCD) or Ground Fault Circuit Interrupt (GFCI)
having a rated residual operating current not exceeding 30 mA.
If the RCD/GFCI device trips, it means there is fault on the power line or motor. Do not use this
pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using. Press the reset button to reset the RDC/GFCI devices after fixed. It
will keeps the circuit shut off and will not reset if the power line problem is not fixed.
It is recommend to test the RCD/GFCI at least once a month.
RCD
NEMA GFCI R
eceptacle
NE
MA GFCI
Breaker
Pumps should be shipped with Power cord with plug for corresponding countries. If there is not power
cord attached to the pump, it is necessary to follow the local electricity power line color code to
connect the power according to the wiring for individual pump diagram.