DPSI V-Match Operating Instructions Version 1.0
Page 13 of 16
The "distance" of the maximum position of a servo in respect to its
center must be at least 20%, otherwise the value is not programmable.
Range checking accompanies each programming. It is therefore not
possible to position the servo center position off limits. Malfunctions are
avoided this way (e.g. V-curve of the servo).