DPSI V-Match Operating Instructions Version 1.0
Page 8 of 16
2.2. Calibrating Servo Center
Programming also starts by positioning the
magnet close to the red dot ("PRG"). The
slave servo makes a short move after 2.5
seconds (just like for servo reverse). The
magnet now is not removed, but rather remains at the "PRG" position.
The stick or switch actuator must not be moved now, i.e. it must remain
in center position. After 5 seconds, the servo makes a short move
again. Now, programming of servo center is active.
The master servo now remains centered and does not move anymore,
even if the stick is moved. With each movement of the transmitter stick
out of center, the servo position (servo center) is incremented or
decremented by one step.
If the stick remains in one end-position, steps automatically increment
or decrement after 2.5 seconds. This serves for quicker settings of the
values.
Hint:
Due to the high resolution of the DPSI V-Match, changes of the servo position
are possibly recognizable only after several steps.