104 100-214-251 REV. 05
Error 16 x
ULS Lost Waiting for TRS Latchable - After the ULS input
became inactive, the ULS input became active again before
the TRS input became active.
Error 17 x
LLS Function Latchable - The LLS input met the conditions for
an LLS error as defined by the LLS control DIP switches. For
further information, refer to 4.11.1 Setting DIP Switches
Selecting DIP Switches.
Error 18 x
Power Supply Module Startup Overload Latchable - The SPM/
AT (System Protection Monitor) indicated a power supply
overload within the first 50 ms of operation.
Error 19 x x
Power Supply Module Overload Error Latchable - The AUPS
indicated a power supply module overload within the first 60
ms of operation.
Error 20 x
NOVRAM Data Latchable - The data read from non-volatile
memory did not pass a data integrity check. If the power
supply cannot read the parameter settings stored in NOVRAM
at power-up, the factory-set settings are used.
Error 21 x x
SV Active Error Non-Resettable - The SV drive output did not
meet the requirements for activating the SV. This error
cannot be cleared by RESET, or by the external RESET input.
Error 23 x
ULS Lost Waiting for TRS Latchable - After the ULS input
became inactive, the ULS input became active again before
the PTS input became active (PTS enabled).
Error 24 x
PTS Lost Waiting for TRS Latchable - After the PTS input
became active, the PTS input became inactive again before
the TRS input became active.
Error 25 x
SV Deactive Error Non-Resettable - The SV drive output did
not meet the requirements for deactivating the solenoid
valve. This error cannot be cleared by RESET, or by the
external RESET input.
Error 26 x
START SWITCH 2 Lost Non-Latching - START SWITCH 2 was
lost before the trigger became active.
Error 27 x
SV Safety Error Non-Resettable - SV drive safety circuit is not
working. This error cannot be cleared by RESET, or by the
external RESET input.
Error 28 x
START SWITCH 2 Stagger Error Non-Latching -START
SWITCH 2 was not pressed within 200 ms after START
SWITCH 1 was pressed.
Error 29 x
START SWITCH 1 Stagger Error Non-Latching - START
SWITCH 1 was not pressed within 200 ms after START
SWITCH 2 was pressed.
Error 30 x Time Limit Error Latchable - Minus time limit not reached.
Table 6.11 Error Codes
Error
Code
IW IW+ Description
100-214-251 IWoper.book Page 104 Friday, June 16, 2017 4:12 PM