100-214-251 REV. 05 61
4.7 Guards and Safety Equipment
4.7.1 Emergency Stop Control
If you use the Emergency Stop button on the Welder to terminate a weld, twist the button
to reset it. (The welder will not operate until this button is reset.) If you are running
automation, you can use external reset that is connected to your User I/O board.
Figure 4.17Integrated Welder Emergency Stop Button
If you are using an Emergency Stop signal from the Start Switch cable, you must clear the
Emergency Stop condition before the System will operate.
Column
Base
Start SwitchStart Switch
Emergency Stop Button
100-214-251 IWoper.book Page 61 Friday, June 16, 2017 4:12 PM