30
Epsilon Ei DeviceNet Drive Reference Manual
DN Status Minor Recoverable Fault
Ei-DN Modbus Address: 14001
A Minor Recoverable Fault occurs when the drive experiences a connection time-out. This
fault will not disable the bridge and will clear after the fault clears.
DN Status Minor Unrecoverable Fault
Ei-DN Modbus Address: 14002
A Minor Unrecoverable Fault will initiate when any of the following faults occur: Encoder
State, Encoder Hardware, Low DC Bus, High DC Bus, Overspeed, Following Error, Shunt
Power RMS. Minor Unrecoverable Faults can only be reset with a cycle of power to the drive.
DN Transmit Counter
Ei-DN Modbus Address: 34201-34202
The DN Transmit Counter keeps a running total of all DeviceNet packets successfully transmitted
to the Master on the DeviceNet network.
DN Vendor ID
Ei-DN Modbus Address: 34001
DN Vendor ID indicates the ODVA (Open DeviceNet Vendors Association) vendor specific
number. The Motion Made Easy Vendor ID is 553.
Range Units Default Type DN Type Group NVM Res. Access
True/False BIT BOOL No RO
Range Units Default Type DN Type Group NVM Res. Access
True/False BIT BOOL No RO
Range Units Default Type DN Type Group NVM Res. Access
0-2
31
-1 Counts US32 UDINT No RO
Range Units Default Type DN Type Group NVM Res. Access
US16 UINT No RO