23
Configuring the DeviceNet Network
Figure 9: Watch Window
DN Allocation Choice (Connections Established)
Ei-DN Modbus Address: 34003
This parameter monitors the status of the established connections and displays the corresponding
bitmap. Bit 0 Explicit Message, Bit1 Polled.
DN Allocation Master MacID
Ei-DN Modbus Address: 34004
This parameter displays the MacID of the master used to control the Ei-DN. The DN Allocation
Master MacID parameter defaults to 63 when no master is controlling it.
Range Units Default Type DN Type Group NVM Res. Access
BM16 WORD No RO
Range Units Default Type DN Type Group NVM Res. Access
0-63 63 US16 UINT No RO