The defective bearing was removed and Figure 5-7 shows the developing problem that was
the source of the impacting. After replacing the bearing, the PeakVue vibration is
significantly reduced, as shown in Figure 5-8, indicating that the problem has been
resolved.
Defective bearingFigure 5-7:
Velocity, PeakVue, and temperature
MHM-97408, Rev 15 97