Connecting two sensorsFigure 3-9:
A. Connector 1 – two red wires, one from each accelerometer
B. Connector 2 – white wire from one accelerometer
C. Connector 3 – white wire from other accelerometer
D. Connector 4 – two black wires, one from each accelerometer
Setup
80 MHM-97408, Rev 15