EasyManuals Logo

Emerson Digitax ST User Manual

Emerson Digitax ST
210 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #45 background imageLoading...
Page #45 background image
Safety
Information
Product
information
Mechanical
installation
Electrical
installation
Getting
started
Basic
parameters
Running the
motor
Optimization
EtherCAT
interface
SMARTCARD
Operation
Onboard
PLC
Advanced
parameters
Technical
Data
Diagnostics
UL listing
information
Digitax ST User Guide 45
Issue: 5
Figure 5-4 Mode examples
When changing the values of parameters, make a note of the new
values in case they need to be entered again.
For new parameter-values to apply after the AC supply to the drive is
interrupted, new values must be saved. Refer to section 5.6.5 Saving
parameters on page 46.
5.6.3 Menu structure
The drive parameter structure consists of menus and parameters.
The drive initially powers up so that only menu 0 can be viewed. The up
and down arrow buttons are used to navigate between parameters and
once level 2 access (L2) has been enabled (see Pr 0.49) the left and
right buttons are used to navigate between menus. For further
information, refer to section 5.6.7 Parameter access level and
security on page 46.
Figure 5-5 Parameter navigation
The menus and parameters roll over in both directions.
i.e. if the last parameter is displayed, a further press will cause the
display to rollover and show the first parameter.
When changing between menus the drive remembers which parameter
was last viewed in a particular menu and thus displays that parameter.
Figure 5-6 Menu structure
Pr value
5.05
Menu 5. Parameter 5
Parameter
View Mode
Healthy Status Alarm Status Trip Status
Status Mode
Drive status =
tripped
Trip type (UU =
undervolts)
Do not change parameter values without careful
consideration; incorrect values may cause damage or a
safety hazard.
*Can only be used to move between menus if L2 access
has been enabled (Pr 0.49). Refer to section
5.6.7 Parameter access level and security on page 46.
WARNING
NOTE
NOTE
*
*
Menu 0
....XX.00....
0.50
0.49
0.48
0.47
0.46
0.01
0.02
0.03
0.04
0.05
M
e
n
u
2
2
M
e
n
u
1
M
e
n
u
2
M
e
n
u
2
1
2
2
.
2
9
2
2
.
2
8
2
2
.
2
7
2
2
.
2
6
2
2
.
2
5
2
2
.
0
1
2
2
.
0
2
2
2
.
0
3
2
2
.
0
4
2
2
.
0
5
1
.
0
1
1
.
0
2
1
.
0
3
1
.
0
4
1
.
0
5
1
.
5
0
1
.
4
9
1
.
4
8
1
.
4
7
1
.
4
6
Moves
between
parameters
Moves between Menus

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Digitax ST and is the answer not in the manual?

Emerson Digitax ST Specifications

General IconGeneral
BrandEmerson
ModelDigitax ST
CategoryController
LanguageEnglish

Related product manuals