Document Part # 026-4283 Rev 0 Page 2 of 8
©2022 Emerson Digital Cold Chain, Inc. This document may be photocopied for personal use.
Visit our website at www.climate.emerson.com for the latest technical documentation and updates.
1 General Warnings
PLEASE READ BEFORE USING THIS MANUAL
SAFETY PRECAUTIONS
2 General Description
XEV20D is a stepper valve actuator intended either for bipolar stepper valves or unipolar stepper valves. This
device has been used with ISaGRAF® environment and with programmable devices of iPRO series or in
combination with instruments of i-CHILL 200CX series.
The maximum configuration of hardware is equipped with:
2 configurable valve outputs to drive bipolar or unipolar valves
Pb1/Pb2 configurable analog inputs: NTC/PTC/Pt1000
Pb3/Pb4 configurable analog inputs: 4 to20mA/0 to5V/Pt1000
CanBus serial line
LAN to communicate with instrument of the same series or devices of i-CHILL200CX series
This manual is part of the product and should be kept near the instrument for easy and quick
reference.
The instrument shall not be used for purposes different from those described hereunder. It
cannot be used as a safety device.
Check the application limits before proceeding.
Check if the supply voltage is correct before connecting the instrument.
Do not expose to water or moisture: use the controller only within the operating limits avoiding
sudden temperature changes with high atmospheric humidity to prevent formation of
condensation.
Warning: Disconnect all electrical connections before any kind of maintenance.
Fit the probe where it is not accessible by the end user. The instrument must not be opened.
In case of failure or faulty operation send the instrument back to the distributor or to
“Dixell S.p.A.” with a detailed description of the fault.
Consider the maximum current which can be applied to each relay (see Technical Data).
Ensure that the wires for probes, loads and the power supply are separated and far enough from
each other, without crossing or intertwining.
In case of applications in industrial environments, the use of mains filters (our mod. FT1) in
parallel with inductive loads could be useful.