69
Setting Up Parameters
Caution
The Line voltage must never be set to 115 VAC if the applied voltage is actually 230
VAC. This can cause drive instability and failure.
Inputs Tab
This tab is divided into two windows: The “Input Functions” window, on the left side,
displays the input functions available, the function polarity and the always active state. The
“Input Lines” window, on the right side, displays the drive enable and four input lines, the
debounce value and input function assignments.
Figure 50: Inputs Tab
Input Functions Window
This window allows you to select the input function you wish to assign to an input line.
Active State
The active state of each input function is displayed next to the output function. See the
"Active Off" check box section on the following page.
Always Active
The setting for Always Active is displayed next to each input function. See "Always Active"
check box section on the following page.