20
Safety Information Product Overview Installation Diagnostics
Options and
Accessories
Specification
Figure 16: Epsilon EP - NT/MG Motor Power Wiring Diagram
NT or MG Motor
Power Connection
R
S
T
Ground
Connector Shell
Brown
Black
Blue
Green/Yellow
Shield
Important: PE ground
should connect to drive
and motor only. Nothing
should be connected
between these devices.
2" and 3" motor cable
connector (CMDS-xxx cable)
Wire crimp ferrules are recommanded:
For ground lead use -
Pheonix Contact p/n AI-TWIN 2X1, 5-8Bk/32 00 82 3
American Electrical/DigiKey 1381015/288-1130-ND
For motor leads use -
Pheonix Contact p/n AI 1,5-8 RD/32 01 13 6 or
ALTEC p/n H1.5/14 2204.0 Pk/100
Tighten screws to 5 in-lb.
EP204-I00-0000
9606XX-XX A1
SN 0610E014
Front View
24 Vdc
R
S
T
MOTOR
L1
L2
PE