EasyManua.ls Logo

Emerson Epsilon EP Drive 400518-01 - Fault Descriptions

Emerson Epsilon EP Drive 400518-01
88 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
44
Safety Information Product Overview Installation Diagnostics
Options and
Accessories
Specification
Fault Descriptions
Flash Invalid
This fault indicates that the firmware checksum has failed. From the Tools>Program Flash menu in PowerTools Pro
the firmware stored in flash memory can be reprogram or upgrade. If this problem persists, call Control Techniques.
A common cause would be an interrupted F/W Flash upgrade (cable disconnected during an upgrade process).
Power Up Test
This fault indicates that the power-up self-test has failed. This fault cannot be reset with the reset command or reset
button.
Motor Overtemp
Allow Motor to cool down,
Reset Button or Input Line
Yes
RMS Shunt Power Reset Button or Input Line Yes
Overspeed Reset Button or Input Line Yes
Following Error
(Pulse mode only)
Reset Button or Input Line Yes
Travel Limit +/- Auto No
Sync Fault Cycle Logic Power Yes
Run Time
(EP-P Only)
Reset Button or Input Line Yes
All "On"
Normally "On" for one second during power-
up
Yes
Display Fault Action to Reset Bridge Disabled

Table of Contents