Chapter 5  Parameter Introductions      69 
EV2000 Series Universal Variable Speed Drive    User Manual 
Binary settings  Hex value 
(Displaying of LED)
Bit3  Bit2  Bit1  Bit0 
1 0 1 0  A 
1 0 1 1  B 
1 1 0 0  C 
1 1 0 1  D 
1 1 1 0  E 
1 1 1 1  F 
 Note: 
Factory setting of all the terminals is positive logic. 
5.9  Display (Group F8) 
F8.00 Language selection 
Range:0~1【0】 
0:Chinese 
1:English 
F8.00 is effective for the panel with LCD screen. 
F8.01 Displayed parameter 
group 1 during operation 
Range:000~3FFH
【3FFH】 
A
 
 B  
 
C
  D
BIT0: output freq. Hz
(before compensation)
BIT1: output freq. Hz
(after compensation)
BIT2: preset freq. 
Hz
BIT3: output current A
BIT0 : running speed 
rpm
BIT1: preset speed rpm
BIT2: running line speed m/s
BIT3: preset line speed m/s
BIT0: output power
BIT1: output torque 
%
BIT2: reserved
BIT3: reserved
BIT0: reserved
BIT1: reserved
BIT2: reserved
BIT3: reserved
 
Fig. 5-52 LED displayed parameter group 1 in operation 
Where, 
A: thousand’s place     B: Hundred’s place 
C: Ten’s place          D: Unit’s place 
F8.01 and F8.02 define the parameters that can be 
displayed by LED in operating status. 
If Bit is 0, the parameter will not be displayed; 
If Bit is 1, the parameter will be displayed. 
For example, Unit place of LED (Bit0) is to display the 
“output frequency before compensation”, if Bit0=0, the 
parameter will not be displayed, if Bit0=1, the parameter 
will be displayed. 
See F7.35 for the relationship between the values of 
each Bit and the displayed value of LED. 
F8.02 Displayed parameter 
group 2 during operation 
Range:000~3FFH
【000H】 
A  
 
B
 
  C 
 
D
BIT0: output volt V
BIT1: DC bus volt
 V
BIT2: VCI     V
BIT3: CCI     V
BIT0: closeloop feedback
%
BIT1: closeloop reference%
BIT2: external counting value
BIT3: terminal status
BIT0
: actual length
BIT1: preset length
BIT2: reserved
BIT3: reserved
BIT0: reserved
BIT1: reserved
BIT2: reserved
BIT3: reserved
 
Fig. 5-53 Operating parameter 2 displayed by LED 
Where, 
A: thousand’s place      B: Hundred’s place 
C: Ten’s place          D: Unit’s place 
The terminal information includes status of terminal 
X1~X8, bi-direction open-collector output terminals Y1 
and Y2, and relay output terminal TC. The status of 
terminals are indicated by the “On” or “Off’ of LED. If the 
LED turns on, that means the terminal is enabled, and 
the terminal is disabled if the LED turns off, as shown in 
Fig.5-54: 
 
Fig. 5-54 Terminal status 
In Fig.5-54, the LEDs display that terminals X1, X2, X4, 
X5 and X8 are enabled, terminals X3, X6 and X7 are 
disabled, terminals Y1 and TC are enabled and terminal 
Y2 is disabled. The central four LEDs always illuminate 
for the convenience of observation. 
 Note: 
When the rotating speed and line speed are displayed, these 
values can be revised by pressing  ▲ and ▼ directly (no 
need to switch to frequency displaying status). 
When F8.01 and F8.02 are all set to 0, the frequency before 
compensation will be displayed.