Emerson FB1100 Flow Computer Quick Start Guide
D301785X012
March 2019
2
Required Tools
Certain tools and equipment are required for installing and servicing the flow computer.
Table 1: Required Tools
Tool
Use
Torque wrench
For bolting/mounting the flow
computer
2.5 mm hexagonal wrench
For manipulating rotation set screw
3 mm hexagonal wrench
For screw for M4 x 0.7 end cap retaining clamp (ATEX
required)
9/16 in hexagonal wrench
For installing/removing ¾ in NPT conduit plugs
1 1/16 in combination wrench
For installing/removing ¾ in NPT to M20 thread
reducer (ATEX required)
High-wattage soldering iron and solder
For tinning ground connection wire
#1 Phillips-head screwdriver
For screws on HMI module
#2 Phillips-head screwdriver
For screws on other modules and boards
1/8 inch flat-head screwdriver
For 5.08 mm pitch terminal block connections
Laptop PC running Field Tools with FBxConnect
configuration software
For software configuration