Emerson FB1100 Flow Computer Quick Start Guide
D301785X012
March 2019
7
Use the following bolt installation procedure:
1. Carbon steel bolts do not require lubrication. Stainless steel bolts are factory-coated with a
lubricant to ease installation. Do not apply any additional lubricant when installing either
type of bolt.
2. Finger-tighten the bolts.
3. Torque the bolts to the initial torque value using a crossing pattern. See Table 2 for
initial torque value.
4. Torque the bolts to the final torque value using the same crossing pattern. See Table 2 for
final torque value.
5. Verify that the flange bolts protrude through the sensor module before applying
pressure.
Table 2: Torque Values for the Flange and Flange Adapter Bolts
Bolt
material
Initial torque
Final torque
Carbon
Steel (CS)
300 in. -lbs.
(33.9 N m)
650 in. -lbs.
(73.4 N m)
Stainless
Steel (SST)
150 in. -lbs.
(16.9 N m)
300 in. -lbs.
(33.9 N m)