3.1 Operating Media
1. Use clean, dry, or lubricated air or inert gas.
2. Maximum pressure: 8 bar/116 psi.
NOTE:
On applications where the spring stroke of single acting actuators is pneumatically
operated, the maximum pressure is 6.5 bar/95 psi.
3. Dew point 10 K below operating temperature.
4. For subzero applications take appropriate measures.
3.2 Operating Temperature Range
Using standard seals and grease the operating temperature range is -20 °C to +100 °C
(-4 °F to +212 °F) as is indicated on the product label. Other medias and temperatures may
be used but consult your local Hytork supplier for conrmation as to suitability.