Do you have a question about the Emerson Liebert GXT3-5000RT230 and is the answer not in the manual?
Input Voltage | 230 VAC |
---|---|
Output Voltage | 230 VAC |
Form Factor | Tower |
Output Voltage Regulation | ±1% |
Output Waveform | Sine Wave |
Input Frequency | 40 - 70 Hz |
Efficiency | Up to 92% |
Capacity | 5000 VA |
Battery Type | Sealed Lead-Acid (SLA) |
Topology | Online Double Conversion |
Output Frequency | 50/60 Hz ± 0.1% |
Typical Recharge Time | 3 hours to 90% |
Communication | USB, RS-232 |
Typical Backup Time | Varies by load |
Communication Interface | USB, RS-232 |
Manual contains important safety instructions for operating the uninterruptible power system (UPS).
Precautions for battery handling, general operation, and IT power system configuration.
Details EMC compliance, potential interference, and environmental disposal guidelines for EU customers.
Explains TVSS/EMI/RFI filters, Rectifier/PFC, Inverter, and Battery Charger functions.
Details the DC-to-DC Converter, Battery system, and Dynamic Bypass functionality.
Describes the main cabinet, including front and rear views and key features.
Details internal battery packs and the removable power distribution box.
Instructions for installing the main UPS cabinet in tower or rack configurations.
Covers rack-mount installation and the adjustable rack-mount kit.
Instructions for connecting external battery cabinets and input/output power.
Explains electrical connections via the removable power distribution box.
Lists program features and the necessary items for setup and operation.
Describes the ON/Alarm Silence/Manual Battery Test and Standby/Manual Bypass buttons.
Explains the LED bars that indicate load level and battery capacity.
Explains the symbols used for UPS status indication and their meanings.
Covers startup checklist, initial electrical checks, and startup sequence.
Details bypass, shutdown, input power disconnection, and maintenance bypass procedures.
Procedure for configuring the IT Power System Access Cover.
Describes the terminal block and its shutdown functions (Any Mode, Battery Mode).
Covers battery signals and optional Liebert IntelliSlot communication cards.
Information on Liebert MultiLink and the Remote Emergency Power Off (REPO) connector.
Step-by-step instructions for safely replacing the internal battery pack.
Information on battery charging, storage, and general safety precautions.
Recommendations for periodically checking UPS status and functions.
Identifies common UPS symptoms and explains indicator lights for diagnostics.
Describes audible alarms and provides a troubleshooting table for common UPS issues.
Details specifications for different UPS models, including dimensions, weight, and AC parameters.
Lists power distribution box specs, temperature parameters, and agency compliance.
Details specifications for external battery cabinets.
Provides battery run time data for various load percentages and battery configurations.
Explains how the UPS learns and modifies estimated run times as batteries age.