7.2 HART/analog single loop wiring
HART/analog single loop wiringFigure 7-2:
B
A
A. 820 Ω maximum loop resistance
B. HART-compatible host or controller
Note
For HART communications:
600 Ω maximum loop resistance
250 Ω minimum loop resistance
I/O wiring for Model 1700 and Model 2700 transmitters with analog outputs