Integratethemeterwiththecontrolsystem
Prerequisites
IfyouareusingtheHARTvariables,beawarethatchangingthecongurationofmAOutput
ProcessVariablewillchangethecongurationoftheHARTPrimaryVariable(PV)and/orthe
HARTSecondaryVariable(SV).
OptionsformAOutputProcessVariable
Table2-2OptionsformAOutputProcessVariable
ProcessvariableDisplaycodeProLinkIIcodeCommunicatorcode
MassowrateMFLOW
MassFlowRate
Masso
VolumeowrateVFLOW
VolumeFlowRate
Volo
Gasstandardvolume
owrate
(1)
GSVFGasStdVolFlowRateGasvolo
TemperatureTEMPTempTemp
Density
DENS
DensityDens
Externalpressure
(1)
EXTPExternalPressureExternalpres
Externaltemperature
(1)
EXTTExternalT emperatureExternaltemp
Temperature-corrected
density
(2)
TCDENAPI:T empCorrectedDensityTCDens
Temperature-corrected
(standard)volumeow
rate
(2)
TCVOLAPI:T empCorrectedVolume
Flow
TCVol
Drivegain
DGAINDriveGain
Drivsignl
Averagecorrected
density
(2)(3)
AVEDAPI:AvgDensity
TCAvgDens
Averagetemperature
(2)(3 )
AVETAPI:AvgT emperature
TCAvgTemp
Densityatreference
temperature
(4)
RDENSCM:Density@ReferenceEDDensatRef
Specicgravity
(4)
SGUCM:Density(FixedSGunits)EDDens(SGU)
Standardvolumeow
rate
(4)
STDVCM:StdVolFlowRateEDStdVolo
Netmassowrate
(4)
NETM
CM:NetMassFlowRateEDNetMasso
Netvolumeowrate
(4)
NETV
CM:NetVolFlowRateEDNetVolo
Concentration
(4)
CONCCM:ConcentrationEDConcentration
Baume
(4)
BAUME
CM:Density(FixedBaume
Units)
EDDens(Baume)
(1)Requirestransmittersoftwarev5.0orlater.
(2)Availableonlyifthepetroleummeasurementapplicationisenabledonyourtransmitter.
(3)Requirestransmittersoftwarev3.3orlater.CanbeassignedonlyviathedisplayorProLinkIIv1.2orlater.
(4)Availableonlyiftheconcentrationmeasurementapplicationisenabledonyourtransmitter.
CongurationandUseManualSupplement
5