Output signals
Measurement variables Mass flow
Temperature
Accuracy and flow rate
Accuracy and flow rate LNGS06 LNGM10
Batch accuracy ±1.0% of batch ±0.5% of batch
Temperature accuracy ±1.0 °C ±0.5% of reading (proc-
ess temperature: -100 to 60 °C)
±1.0 °C ±1.0% of reading (proc-
ess temperature: -196 to
-100 °C)
±1.0 °C ±0.5% of reading (proc-
ess temperature: -100 to 60 °C)
±1.0 °C ±1.0% of reading (proc-
ess temperature: -196 to
-100 °C)
Maximum flow rates for liquids 1800 kg/hr 18000 kg/hr
Note
For determining the performance capabilities of our meters, the typical batch/dispensing flow rates
are defined as follows:
Batch time is no less than 3 minutes.
The LNGM10 flow rate is no less than 20 kg/min and the LNGS06 flow rate is no less than 2 kg/
min.
Fluid is liquid nitrogen or LNG.
Basic configuration
Quick Start Guide 25

Other manuals for Emerson Micro Motion

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Micro Motion and is the answer not in the manual?

Emerson Micro Motion Specifications

General IconGeneral
CategoryMeasuring Instruments
ManufacturerEmerson
BrandMicro Motion
TypeCoriolis Flow Meter
Output4-20 mA, HART, Foundation Fieldbus, Profibus, Modbus
Power Supply24 V DC
MaterialStainless Steel, Hastelloy
Process ConnectionFlanged, Threaded
CertificationsATEX, IECEx, CSA, SIL
Pressure RatingVaries by model; up to 10, 000 psi (690 bar)
Temperature RangeVaries by model; -400 to 750°F (-240 to 400°C)