Lists CE/FCC compliance, Part 15, UL, and CSA standards for the RLDS.
Guidance on utilizing the manual for RLDS installation and operation.
Notes on manual usage, Emerson's rights, and error reporting.
Comprehensive safety guidelines covering power, grounding, atmosphere, venting, and modifications.
Procedures for malfunctions, fusing requirements, installation category, altitude, and cleaning.
Overview of RLDS features, zone monitoring, alarms, and fault indicators.
Details communication options via RS485 and understanding monitoring levels.
Discusses response to multiple refrigerants and optimal location of sampling points.
Factors to consider before installation, including inspection and location selection.
Instructions for mounting the unit and connecting sample, purge, and exhaust air lines.
Details splitter kit usage, installation, and an overview of the RLDS interior.
Guidelines for RLDS electrical wiring, including safety warnings and connection procedures.
Explains connecting RLDS to E2 controllers via MODBUS, including port associations and setup.
Covers powering, networking, and connecting the RLDS Gateway Board to controllers.
Details wiring connections, dip switch settings, and termination for the Gateway Board.
Explains the meaning of the status LEDs on the RLDS Gateway Board.
Describes relay assignments for alarms and provides wiring instructions for external devices.
Introduces navigation keys and the process for initial setup screens.
Guides through navigating setup screens and configuring parameters like location, zones, and alarms.
Covers node address, password, additional features, digipot, and service timeout settings.
Explains the Zone screen, displaying location, refrigerant, PPM readings, and log intervals.
Details how alarms and faults are indicated, responded to, and acknowledged.
Covers navigating fault screens, critical/non-critical faults, and clearing faults.
Guides on viewing fault logs, flow logs, and resetting them.
Explains navigating the Trend screen and the Calibration screen for factor adjustment and new gases.
Details the Diagnostic screen for sensor data and troubleshooting fault conditions.
Describes how to enter and exit Service Mode for unit disabling and maintenance.
Guides on setting time/date and configuring general zone parameters using the HHT.
Details setting zone alarm levels and viewing zone/controller status via HHT.
Details general configuration, zone setup, and calibration screens accessible through HHT.
Describes the Home, Enable, and Select RLDS screens on the HHT.
Covers selecting RLDS options, viewing faults, and accessing configuration screens via HHT.
Details general configuration, zone setup, and calibration screens accessible through HHT.
Guides on setting up RLDS units using REFLECS and older E2 controller interfaces.
Details the steps for setting up RLDS units with an Einstein controller.
Covers safety warnings, charcoal filter, hydrophobic filter, and air line servicing.
Outlines the recommended annual maintenance tasks, including diagnostics and filter replacement.
Explains the calibration check process and gas testing procedures using verification kits.