Field Communicator Menu Trees and Fast Keys
July 2018
Reference Manual
00809-0200-4728, Rev SA
Field Communicator Menu Trees and Fast Keys
90
Figure B-2. Configure
Home
1 Overview
2 Configure
3 Service Tools
Configure
1 Guided Setup
2 Manual Setup
Noise Rejection
1 AC Power Filter
2 Transient Filter
Security
1 Software Write Protect
2 HART Lock
3 Local Operator Interface*
Analog Output
1 Analog Output Value
2 Percent of Range
3 Primary Variable
4 Param
5 PV Configuration
6 Alarm/Sat Levels
Burst Mode Config
1 Burst Message 1
2 Message 1 Content
3 1st and Trigger Value
4 Second Variable
5 Third Variable
6 Fourth Variable
7 Config Adt’l Messages
Variable Mapping
1 Primary Variable
2 Second Variable
3 Third Variable
4 Fourth Variable
5 Re-Map Variables
Device Information
1 Tag
2 Long Tag
3 Date
4 Description
5 Message
6 Final Assembly Num
HART
1 Polling Address
2 Change Polling Address
3 HART Universal Rev
4 Change HART Rev
5 Burst Mode Config
6 Variable Mapping
Alarm/Sat Levels
1 Alarm Direction
2 High Alarm
3 High Saturation
4 Low Saturation
5 Low Alarm
6 Config Alarm/Sat Levels
Guided Setup
1 Configure Sensors
2 Calibrate Sensors
3 Configure Device
4 Configure Display
5 Config Hot Backup
6 Config Drift Alert
7 Diagnostics Suite
Manual Setup
1 Sensor 1
2 Sensor 2
3 Calculated Output
4 Diagnostics
5 Analog Output
6 Display
7 Device
8 HART
9 Security
Sensor 1
1 Sensor 1 Temp
2 Sensor 1 Status*
3 Sensor 1 Type
4 Sensor 1 Connection
5 Engineering Units
6 Damping
7 Serial Number
8 Sensor Limits
9 Sensor Matching-CVD
10 2-Wire Offset
Sensor 2
1 Sensor 2 Temp
2 Sensor 2 Status*
3 Sensor 2 Type
4 Sensor 2 Connection
5 Engineering Units
6 Damping
7 Serial Number
8 Sensor Limits
9 Sensor Matching-CVD
10 2-Wire Offset
Calculated Output
1 Differential Temperature*
2 First Good Temperature*
3 Average Temperature*
Display
1 Variables Displayed
2 Decimal Places
3 Bar Graph*
Diagnostics
1 Hot Backup
2 Sensor Drift Alert
3 Sensor and Process Diagnostics
Device
1 Device Information
2 Terminal Temp Units
3 Open Sensor Hold Off
4 Noise Rejection
PV Configuration
1 Primary Variable
2 Upper Range Value
3 Lower Range Value
4 Minimum Span

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Rosemount 644 with HART Protocol and is the answer not in the manual?

Emerson Rosemount 644 with HART Protocol Specifications

General IconGeneral
BrandEmerson
ModelRosemount 644 with HART Protocol
CategoryTransmitter
LanguageEnglish

Related product manuals