Quick Start Guide
7
September 2016
Figure 7. Remote Electronics Installation
A.
1. If you plan to run the coaxial cable in conduit, carefully cut the conduit to the
desired length to provide for proper assembly at the housing. A junction box
may be placed in the conduit run to provide a space for extra coaxial cable
length.
2. Slide the conduit adapter or cable gland over the loose end of the coaxial
cable and fasten it to the adapter on the meter body support tube.
3. If using conduit, route the coaxial cable through the conduit.
4. Place a conduit adapter or cable gland over the end of the coaxial cable.
5. Remove the housing adapter from the electronics housing.
6. Slide the housing adapter over the coaxial cable.
A. Meter body J. Electronics housing
B. Support tube K. Ground connection
C. Sensor cable nut L. Housing base screw
D. Nut M. Housing adapter
E. Washer N. Housing adapter screws
F. Union
G. Meter adapter
O.
1
/2 in. NPT conduit adapter or cable gland
(supplied by customer)
H. Coaxial cable P. Coaxial cable nut
I.
1
/2 in. NPT Conduit adapter or cable
gland (supplied by customer)
The coaxial remote cable cannot be field terminated or cut to length. Coil any extra coaxial cable with no
less than a 2-in. (51 mm) radius.
A
Note: Consult factory for SST installation.