Table 1. Fast Keys for Rosemount 8800D Device Revision 1 DD Revision 2 and Device Revision 2 DD
Revision 1
Function HART Fast Key Function HART Fast Key
Alarm Jumpers 1, 4, 2, 1, 3 Meter Body Number 1, 4, 1, 5
Analog Output 1, 4, 2, 1 Minimum Span 1, 3, 8, 3
Auto Adjust Filter 1, 4, 3, 1, 4 Num Req Preams 1, 4, 2, 3, 2
Base Time Unit 1, 1, 4, 1, 3, 2 Poll Address 1, 4, 2, 3, 1
Base Volume Unit 1, 1, 4, 1, 3, 1 Process Fluid Type 1, 3, 2, 2
Burst Mode 1, 4, 2, 3, 4 Process Variables 1, 1
Burst Option 1, 4, 2, 3, 5 Pulse Output 1, 4, 2, 2, 1
Burst Variable 1 1, 4, 2, 3, 6, 1 Pulse Output Test 1, 4, 2, 2, 2
Burst Variable 2 1, 4, 2, 3, 6, 2 PV Damping 1, 3, 9
Burst Variable 3 1, 4, 2, 3, 6, 3 PV Mapping 1, 3, 6, 1
Burst Variable 4 1, 4, 2, 3, 6, 4 PV Percent Range 1, 1, 2
Burst Xmtr Variables 1, 4, 2, 3, 6 QV Mapping 1, 3, 6, 4
Conversion Number 1, 1, 4, 1, 3, 4 Range Values 1, 3, 8
D/A Trim 1, 2, 5 Review 1, 5
Date 1, 4, 4, 5 Revision Numbers 1, 4, 4, 7
Descriptor 1, 4, 4, 3 Scaled D/A Trim 1, 2, 6
Density Ratio 1, 3, 2, 4, 1, 1 Self Test 1, 2, 1, 5
Device ID 1, 4, 4, 7, 6 Signal to Trigger Ratio 1, 4, 3, 2, 2
Electronics Temp 1, 1, 4, 7, 1 STD/ Nor Flow Units 1, 1, 4, 1, 2
Electronics Temp Units 1, 1, 4, 7, 2 Special Units 1, 1, 4, 1, 3
Filter Restore 1, 4, 3, 3 Status 1, 2, 1, 1
Final Assembly Number 1, 4, 4, 7, 5 SV Mapping 1, 3, 6, 2
Fixed Process Density 1, 3, 2, 4, 2 Tag 1, 3, 1
Fixed Process Temperature 1, 3, 2, 3 Total 1, 1, 4, 4, 1
Flange Type 1, 3, 4 Totalizer Control 1, 1, 4, 4
Flow Simulation 1, 2, 4 Transmitter Mode 1, 3, 2, 1
Installation Effects 1, 4, 1, 6 TV Mapping 1, 3, 6, 3
K-factor (Reference) 1, 3, 3 Trigger Level 1, 4, 3, 2, 5
Local Display 1, 4, 2, 4 URV 1, 3, 8, 1
Loop Test 1, 2, 2 User Defined Units 1, 1, 4, 1, 3, 3
Low Flow Cutoff 1, 4, 3, 2, 3 USL 1, 3, 8, 4
Low Pass Filter 1, 4, 3, 2, 4 Shedding Frequency 1, 1, 4, 6
LRV 1, 3, 8, 2 Variable Mapping 1, 3, 6
LSL 1, 3, 8, 5 Velocity Flow 1, 1, 4, 3
Manufacturer 1, 4, 4, 1 Velocity Flow Base 1, 1, 4, 3, 3
Mass Flow 1, 1, 4, 2, 1 Volumetric Flow 1, 1, 4, 1
Mass Flow Units 1, 1, 4, 2, 2 Wetted Material 1, 4, 1, 4
Mating Pipe ID (Inside Diameter) 1, 3, 5 Write Protect 1, 4, 4, 6
Message 1, 4, 4, 4