Quick Installation Guide
00825-0100-4004, Rev DB
December 2011
Rosemount 8800D
15
Table 2. Fast Keys for Rosemount 8800D Device Revision 2 DD Revision 3
Function HART Fast Key Function HART Fast Key
Alarm Direction 1, 3, 1, 3, 2 Percent of Range 3, 4, 3, 2
Analog Output 3, 4, 3, 1 Polling Address 2, 2, 7, 1
Analog Trim 3, 4, 3, 6 Primary Variable Damping 2, 1, 4, 1
Base Time Unit 2, 2, 2, 3, 2 Primary Variable 2, 2, 2, 1, 1
Base Volume Unit 2, 2, 2, 3, 1 Process Density Units 2, 2, 2, 2, 6
Burst Mode 2, 2, 7, 2 Process Fluid Type 2, 2, 1, 1, 2
Burst Option 2, 2, 7, 3 Process Temp Units 2, 2, 3, 1, 2
Burst Slot 0 2, 2, 7, 4, 1 Process Variables 3, 2, 1
Burst Slot 1 2, 2, 7, 4, 2 Pulse Output 3, 2, 4, 4
Burst Slot 2 2, 2, 7, 4, 3 Pulse Output Test 3, 5, 3, 4
Burst Slot 3 2, 2, 7, 4, 4 Recall Factory Calibration 3, 4, 3, 8
Burst Variable Mapping 2, 2, 7, 4, 5 Reference K-Factor 2, 2, 1, 2, 1
Compensated K-Factor 2, 2, 1, 2, 2 Reset Transmitter 3, 4, 1, 2
Conversion Number 2, 2, 2, 3, 4 Restore Default Filters 2, 1, 4, 6
Date 2, 2, 8, 2, 1 Revision Numbers 2, 2, 8, 3
Descriptor 2, 2, 8, 2, 2 Scaled Analog Trim 3, 4, 3, 7
Density Ratio 2, 2, 3, 3, 2 2nd Variable 2, 2, 2, 1, 2
Device ID 2, 2, 8, 1, 5 Self Test 3, 4, 1, 1
Display 2, 1, 1, 2 Set Variable Mapping 2, 2, 2, 1, 5
Electronics Temp 3, 2, 5, 4 Shedding Frequency 3, 2, 4, 2
Electronics Temp Units 2, 2, 2, 2, 5 Signal Strength 3, 2, 5, 2
Final Assembly Number 2, 2, 8, 1, 4 Special Flow Unit 2, 2, 2, 3, 5
Fixed Process Density 2, 2, 1, 1, 5 Special Volume Unit 2, 2, 2, 3, 3
Fixed Process Temperature 2, 2, 1, 1, 4 Status 1, 1, 1
Flange Type 2, 2, 1, 4, 2 Tag 2, 2, 8, 1, 1
Flow Simulation 3, 5, 1 3rd Variable 2, 2, 2, 1, 3
4th Variable 2, 2, 2, 1, 4 Total 1, 3, 6, 1
Installation Effects 2, 2, 1, 1, 7 Totalizer Configuration 1, 3, 6, 3
Lower Range Value 2, 2, 4, 1, 4 Totalizer Control 1, 3, 6, 2
Lower Sensor Limit 2, 2, 4, 1, 5, 2 Transmitter Mode 2, 2, 1, 1, 1
Loop Test 3, 5, 2, 6 Trigger Level 2, 1, 4, 5
Low Flow Cutoff 2, 1, 4, 3 Upper Range Value 2, 2, 4, 1, 3
Low-pass Corner Frequency 2, 1, 4, 4 Upper Sensor Limit 2, 2, 4, 1, 5, 1
Manufacturer 2, 2, 8, 1, 2 Velocity Flow 3, 2, 3, 4
Mass Flow 3, 2, 3, 6 Velocity Flow Units 2, 2, 2, 2, 2
Mass Flow Units 2, 2, 2, 2, 4 Velocity Measurement Base 2, 2, 2, 2, 3
Mating Pipe ID (Inside Diameter) 2, 2, 1, 1, 6 Volume Flow 3, 2, 3, 2
Message 2, 2, 8, 2, 3 Volume Flow Units 2, 2, 2, 2, 1
Meter Body Number 2, 2, 1, 4, 5 Wetted Material 2, 2, 1, 4, 1
Minimum Span 2, 2, 4, 1, 6 Write Protect 2, 2, 8, 1, 6
Optimize DSP 2, 1, 1, 3