8 Product certifications
Flameproof enclosure Ex d protection type in accordance with IEC
60079-1, EN 60079-1
• Transmitters with Flameproof enclosure type protection shall only be
opened when power is removed.
• Closing of entries in the device must be carried out using the appropriate
Ex d cable gland or blanking plug. Unless otherwise marked on housing,
the standard conduit entry thread forms are 1/2–14 NPT.
Type n protection type in accordance with IEC 60079-15, EN60079-15
Closing of entries in the device must be carried out using the appropriate Ex e
or Ex n cable gland and metal blanking plug or any appropriate ATEX or IECEx
approved cable gland and blanking plug with IP66 rating certified by an EU
approved certification body.
8.1 European directive information
The CE Declaration of Conformity for all applicable European directives for this
product can be found on our website at www.emerson.com/rosemount. A
hard copy may be obtained by contacting our local sales office.
8.2 ATEX Directive
Emerson Process Management complies with the ATEX Directive.
8.3
European Pressure Equipment Directive (PED)
Rosemount 8800D Vortex Flowmeter line size 40 mm to 300 mm
• Certificate Number 4741-2014-CE-HOU-DNV
•
0575 or 0496
• Module H Conformity Assessment
• Mandatory CE-marking for flowmeters in accordance with Article 15 of the
PED can be found on the flowtube body.
• Flowmeter categories I – III use module H for conformity assessment
procedures.
Rosemount 8800D Vortex Flowmeter line size 15 mm and 25 mm
Sound Engineering
Practice (SEP)
Flowmeters that are SEP are outside the scope of
PED and cannot be marked for compliance with
PED.
Quick Start Guide October 2018
30 Rosemount
™
8800D Series Vortex Flowmeter